PRINCIPLE THERMAL DISPERSION
GAS AIR
CALIBRATION 0 TO 100 ML / MIN (REF .: 21.1 ºC, 1 ATM ABS)
ACCURACY ± 1.0% F.E FOR 0 TO 100% RANGE
REPEATABILITY ± 0.25% F.E
RESPONSE TIME USUALLY 2 SECONDS TO ACHIEVE INSTANT FLOW WITH
DEVIATION OF UP TO ± 2% FOR VALUES BETWEEN 25 AND 100% OF THE FULL SCALE.
TEMPERATURE COEFFICIENT 0.15% F.E / ºC
PRESSURE COEFFICIENT 0.01% F.E / PSI
TIME CONSTANT 800 MS
OUTPUT SIGNALS 0-5 VDC LINEAR, 1000 OHMS MAX.
4-20 MA, 250 OHMS MAX.
POWER (CONSUMPTION) 12 TO 26 VDC (200 MA)
DISPLAY YES, 3.1 / 2 DIGIT LCD
ELECTRICAL CONNECTION DB9 MALE CONNECTOR. CABLE INCLUDED
METALS IN CONTACT WITH GAS ANODIZED ALUMINUM, 316 STAINLESS STEEL AND BRASS
MEASURING BLOCK ANODIZED ALUMINUM
VITON-A SEALS
CONNECTIONS 1/4” BRASS COMPRESSION TERMINAL
TEMPERATURE (AMBIENT AND GAS) 0 TO 50 ° C – USE ONLY IN DRY GASES
MAX SUPPORTED PRESSURE 1000 PSIG (70 BAR)
OPTIMIZED PERFORMANCE: 20 PSIG (1.4 BAR)
PRESSURE DROP SEE CATALOG
TILT SENSITIVITY SHOULD NOT BE GREATER THAN + 15º OF ROTATION FROM THE HORIZONTAL PLANE TO THE
VERTICAL; STANDARD CALIBRATION PERFORMED IN THE HORIZONTAL PLANE.
CONFORMITY CE EN 55011 CLASS 1, CLASS B; EN 50082-1

How to Balance Flexibility and Corporate Compliance in Indirect Procurement
The growth of the digital economy, changes in international production networks and the speed of transportation are changing the way we conduct foreign trade, making processes more inclusive and efficient.