PRESSURE SENSOR
MEDIUM TEMPERATURE [°C] 0…60
PRESSURE RATING [BAR] 20
MIN. BURSTING PRESSURE [BAR] 30
OPERATING VOLTAGE [V] 18…32 DC; (ACCORDING TO EN 50178 SELV/PELV)
CURRENT CONSUMPTION [MA] < 50
MIN. INSULATION RESISTANCE [M©] 100; (500 V DC)
PROTECTION CLASS III
REVERSE POLARITY PROTECTION YES
OVERVOLTAGE PROTECTION YES; (< 40 V)
POWER-ON DELAY TIME [S] 0.3
TOTAL NUMBER OF OUTPUTS 2
OUTPUT SIGNAL SWITCHING SIGNAL
ELECTRICAL DESIGN PNP
NUMBER OF DIGITAL OUTPUTS 2
OUTPUT FUNCTION NORMALLY OPEN / NORMALLY CLOSED; (PARAMETERISABLE)
MAX. VOLTAGE DROP SWITCHING
OUTPUT DC
[V]
2
PERMANENT CURRENT RATING OF
SWITCHING OUTPUT DC
[MA]
100
SWITCHING FREQUENCY DC [HZ] < 200
SHORT-CIRCUIT PROTECTION YES
TYPE OF SHORT-CIRCUIT
PROTECTION
PULSED
MEASURING/SETTING RANGE
MEASURING RANGE [BAR] -1…1
SET POINT SP [BAR] -0.98…1
RESET POINT RP [BAR] -0.99…0.99