Product

GFM17A-VAL6-B0-3AB-04-SS

Details

PRINCIPLE THERMAL DISPERSION
GAS AIR
CALIBRATION 0 TO 100 ML / MIN (REF .: 21.1 ºC, 1 ATM ABS)
ACCURACY ± 1.0% F.E FOR 0 TO 100% RANGE
REPEATABILITY ± 0.25% F.E
RESPONSE TIME USUALLY 2 SECONDS TO ACHIEVE INSTANT FLOW WITH
DEVIATION OF UP TO ± 2% FOR VALUES ​​BETWEEN 25 AND 100% OF THE FULL SCALE.
TEMPERATURE COEFFICIENT 0.15% F.E / ºC
PRESSURE COEFFICIENT 0.01% F.E / PSI
TIME CONSTANT 800 MS
OUTPUT SIGNALS 0-5 VDC LINEAR, 1000 OHMS MAX.
4-20 MA, 250 OHMS MAX.
POWER (CONSUMPTION) 12 TO 26 VDC (200 MA)
DISPLAY YES, 3.1 / 2 DIGIT LCD
ELECTRICAL CONNECTION DB9 MALE CONNECTOR. CABLE INCLUDED
METALS IN CONTACT WITH GAS ANODIZED ALUMINUM, 316 STAINLESS STEEL AND BRASS
MEASURING BLOCK ANODIZED ALUMINUM
VITON-A SEALS
CONNECTIONS 1/4” BRASS COMPRESSION TERMINAL
TEMPERATURE (AMBIENT AND GAS) 0 TO 50 ° C – USE ONLY IN DRY GASES
MAX SUPPORTED PRESSURE 1000 PSIG (70 BAR)
OPTIMIZED PERFORMANCE: 20 PSIG (1.4 BAR)
PRESSURE DROP SEE CATALOG
TILT SENSITIVITY SHOULD NOT BE GREATER THAN + 15º OF ROTATION FROM THE HORIZONTAL PLANE TO THE
VERTICAL; STANDARD CALIBRATION PERFORMED IN THE HORIZONTAL PLANE.
CONFORMITY CE EN 55011 CLASS 1, CLASS B; EN 50082-1