FIXED GAS DETECTOR – XGARD 1/GRN/½/INMETRO/O2/25% VOL
DETECTION PRINCIPLE : ELECTROCHEMICAL CELL
GAS : OXYGEN (O2)
RANGE : 0 ~ 25% VOL.
TEMPERATURE RANGE : – 20 ~ +50°C
ZERO DRIFT : <2% F.S.D
HUMIDITY RANGE : 0 ~ 90% RH (NON-CONDENSED)
REPEATABILITY : <2% F.S.D
BODY MATERIAL AND JUNCTION BOX : NYLON REINFORCED FIBERGLASS
OPERATING VOLTAGE : 8 ~ 30VDC
REQUIRES POWER : 24MA
ELECTRICAL OUTPUT : 2 WIRES ( 4 ~ 20MA)
TERMINALS : 0.5 ~ 2.5 MM²
IP65 PROTECTION, (FOR IP66 DEGREE OF PROTECTION, PLEASE CONSULT)
ELECTRICAL CONNECTION : ½'' NPT
AREA CLASSIFICATION : INTRINSICALLY SAFE
APPROVAL :
ATEX : EX II 1 G EEXIA IIC T4 (T.AMBIENTE : -40 ~ +55ºC) , UL AND CSA , IEC, MED. MARINE (96/98) ONLY O2…
EMC COMPLIANCE : EN 50270
CERTIFICATION : INMETRO
* ACCOMPANIES :
– MANUAL (ENGLISH)
– MANUAL (PORTUGUESE)
– ALUMINIUM CABLE PRESS ½''NPT
– ALL DETECTORS ARE AT LEAST SUPPLIED WITH TRACKED CALIBRATION.
ACCREDITED CALIBRATION CERTIFICATE, FOR 01 POINT(S), ISSUED BY CGRE'S ACCREDITED CALIBRATION LABORATORY ACCORDING TO ABNT NBR ISO 17025, UNDER NUMBER CAL 0435