RATED OPERATING DISTANCE SN 20 MM
MOUNTING CONDITION FLUSH
ASSURED SENSING RANGE Ð (0,81 X SN) MM
CORRECTION FACTORS ST37 = 1; AL = 0.3; STAINLESS STEEL = 0.7; MS = 0.4
REPEATABILITY Ð 2 % OF FULL SCALE
TEMPERATURDRIFT 10 %
HYSTERESIS 3…15 %
AMBIENT TEMPERATURE -25…+70 °C
OPERATING VOLTAGE 20…250 VAC
OPERATING VOLTAGE 10…300VDC
AC RATED OPERATIONAL CURRENT Ð 400 MA
DC RATED OPERATIONAL CURRENT Ð 300 MA
FREQUENCY Ï 50…Ð 60 HZ
RESIDUAL CURRENT Ð 1.7 MA
RATED INSULATION VOLTAGE Ð 1.5 KV
SURGE CURRENT Ð 8 A (Ð 10 MS MAX. 5 HZ)
VOLTAGE DROP AT IE Ð 6 V
OUTPUT FUNCTION 2-WIRE, NC CONTACT
SMALLEST OPERATING CURRENT IM Ð 3 MA
SWITCHING FREQUENCY 0.02 KHZ
DESIGN THREADED BARREL, G47
DIMENSIONS 70 MM
HOUSING MATERIAL METAL, CUZN, CHROME-PLATED
MATERIAL ACTIVE FACE PLASTIC, PA
END CAP PLASTIC, PA66-GF25
MAX. TIGHTENING TORQUE HOUSING NUT 90 NM
CONNECTION CABLE
CABLE QUALITY 5.2 MM, LIFYY, PVC, 2 M
CABLE CROSS SECTION 3 X 0.75 MM2
VIBRATION RESISTANCE 55 HZ (1 MM)
SHOCK RESISTANCE 30 G (11 MS)
PROTECTION CLASS IP67
MTTF 2283 YEARS ACC. TO SN 29500 (ED. 99) 40 °C